<?xml version='1.0' encoding='UTF-8'?><?xml-stylesheet href="http://www.blogger.com/styles/atom.css" type="text/css"?><feed xmlns='http://www.w3.org/2005/Atom' xmlns:openSearch='http://a9.com/-/spec/opensearchrss/1.0/' xmlns:georss='http://www.georss.org/georss' xmlns:gd='http://schemas.google.com/g/2005' xmlns:thr='http://purl.org/syndication/thread/1.0'><id>tag:blogger.com,1999:blog-4301295346690662610</id><updated>2011-11-27T15:42:39.594-08:00</updated><title type='text'>ULTRASENSITIVE ANALYZERS FOR REAL WORLD</title><subtitle type='html'></subtitle><link rel='http://schemas.google.com/g/2005#feed' type='application/atom+xml' href='http://ultrasensitive-analyzers.blogspot.com/feeds/posts/default'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default?max-results=100'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/'/><link rel='hub' href='http://pubsubhubbub.appspot.com/'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author><generator version='7.00' uri='http://www.blogger.com'>Blogger</generator><openSearch:totalResults>14</openSearch:totalResults><openSearch:startIndex>1</openSearch:startIndex><openSearch:itemsPerPage>100</openSearch:itemsPerPage><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-7609657055518649248</id><published>2009-01-13T15:51:00.001-08:00</published><updated>2009-01-13T15:51:59.441-08:00</updated><title type='text'>Hydrogen Fluoride Analyzer</title><content type='html'>* High Precision&lt;br /&gt;    * High Sensitivity&lt;br /&gt;    * Simple to Use&lt;br /&gt;    * Extremely Wide Dynamic Range&lt;br /&gt;    * Economical of Own and Operate&lt;br /&gt;&lt;br /&gt;LGR’s Hydrogen Fluoride Analyzer (HFA) provides sensitive measurements of HF in ambient air or in industrial process flows with extremely high precision and sensitivity. No longer do you have to spend a lot of money or wait a long time to measure HF with extremely high sensitivity – LGR’s HF Analyzer provides measurements every second with ppbv-level precision. In addition, the HFA can report measurements quickly over a very wide range of HF concentrations. The instrument, based on LGR’s cavity enhanced laser absorption spectroscopy, is extremely simple to use, inexpensive to operate, and includes all components (internal vacuum pump, keyboard, mouse, video monitor) to start recording data within minutes. Other atmospheric gases, including water vapor, carbon dioxide, oxygen, and methane, do not interfere with the HF measurements. The instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for unattended long-term operation), and that can send real-time data to a data logger through its analog and digital (RS232 serial) outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive. LGR’s Hydrogen Fluoride Analyzer provides the high quality data necessary for the most demanding trace gas monitoring applications.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-7609657055518649248?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/7609657055518649248'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/7609657055518649248'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/hydrogen-fluoride-analyzer.html' title='Hydrogen Fluoride Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-8625620313666197790</id><published>2009-01-13T15:50:00.002-08:00</published><updated>2009-01-13T15:51:23.105-08:00</updated><title type='text'>Economical Ammonia Analyzer</title><content type='html'>* High Precision&lt;br /&gt;    * High Sensitivity&lt;br /&gt;    * Simple to Use&lt;br /&gt;    * Extremely Wide Dynamic Range&lt;br /&gt;    * Economical of Own and Operate&lt;br /&gt;&lt;br /&gt;LGR’s Economical Ammonia Analyzer (EAA) provides sensitive measurements of ammonia in ambient air or in industrial process flows with extremely high precision and sensitivity. No longer do you have to spend a lot of money or wait a long time to measure ammonia with high sensitivity – LGR’s EAA provides measurements every second with ppbv-level precision. In addition, the EAA can report measurements quickly over a very wide range of ammonia concentrations. The instrument, based on LGR’s cavity enhanced laser absorption spectroscopy, is simple to use, inexpensive to operate, and includes all components (internal vacuum pump, keyboard,mouse, video monitor) to start recording data within minutes. Other atmospheric gases, including water vapor, carbon dioxide and methane, do not interfere with the ammonia measurements. The instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for unattended long-term operation), and that can send real-time data to a data logger through its analog and digital (RS232 serial) outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive. LGR’s EAA provides the high quality data necessary for the most demanding applications including semiconductor process monitoring and atmospheric trace gas monitoring. For customers interested in the highest precision with extremely fast response time, LGR offers the Trace Ammonia Analyzer.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-8625620313666197790?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/8625620313666197790'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/8625620313666197790'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/economical-ammonia-analyzer.html' title='Economical Ammonia Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-5759056123543632582</id><published>2009-01-13T15:50:00.001-08:00</published><updated>2009-01-13T15:50:47.510-08:00</updated><title type='text'>Trace Ammonia Analyzer</title><content type='html'>* Unparalleled Precision&lt;br /&gt;    * Ultra-high Sensitivity&lt;br /&gt;    * Extremely Fast Response&lt;br /&gt;&lt;br /&gt;LGR’s Trace Ammonia Analyzer (TAA) provides fast measurements of ammonia in ambient air with unparalleled precision and sensitivity. No longer do you have to wait for minutes before getting a useful reading – LGR’s TAA provides measurements every second with sub-ppbv precision. In addition, the TAA can report measurements quickly over a wide range of ammonia concentrations. For your convenience, we offer two versions of the TAA. If you require the fastest response rate possible (data rate up to 20 Hz), you will want to use our Trace Ammonia Analyzer - Fast. For applications requiring measurements of NH3 with highest accuracy, you’ll want the Trace Ammonia Analyzer – High Accuracy. In general, LGR Analyzers are not adversely affected by other atmospheric gases (no cross interferences) or changes in atmospheric pressure. Due to our low-power requirements, LGR analyzers may be operated on battery power with an appropriate AC/DC voltage inverter.&lt;br /&gt;&lt;br /&gt;The Trace Ammonia Analyzer - Fast is designed to suit many applications including eddy correlation flux measurements using established micrometeorological techniques, which require response rates above 10 Hz.&lt;br /&gt;&lt;br /&gt;The Trace Ammonia Analyzer – High Accuracy is designed for applications that require the highest sensitivity, precision and accuracy like semiconductor process monitoring and ambient air monitoring.&lt;br /&gt;&lt;br /&gt;For customers interested in a less expensive ammonia analyzer with very high precision and fast response time, LGR offers the Economical Ammonia Analyzer.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-5759056123543632582?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/5759056123543632582'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/5759056123543632582'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/trace-ammonia-analyzer.html' title='Trace Ammonia Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-2124312811648793451</id><published>2009-01-13T15:49:00.001-08:00</published><updated>2009-01-13T15:49:53.798-08:00</updated><title type='text'>Deep-Sea Gas Analyzers</title><content type='html'>The Deep-Sea Gas Analyzer provides an accurate measurement of a variety of gases at depths of up to 2500 meters. The instrument employs a membrane gas extractor and is capable of measuring virtually any gas in LGR’s catalog, including CH4, CO2, and various stable isotopomers. Self-sustained, remote operation is possible using the internal battery, gas handling system, and data storage. Possible applications include carbon sequestration in ocean waters, methane-hydrate studies, and hydrothermal-vent effluent analysis.&lt;br /&gt;As described in the Theory Section (on www.lgrinc.com), the measurement strategy is based on high-resolution direct-absorption spectroscopy. As a result, the instrument is self-calibrating and provides an absolute, accurate gas concentration without reference standards. An internal computer can store data practically indefinitely for applications requiring unattended long-term standalone operation. These analyzers can also send real-time data to a data logger through analog, digital (RS232), and Ethernet outputs.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-2124312811648793451?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/2124312811648793451'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/2124312811648793451'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/deep-sea-gas-analyzers.html' title='Deep-Sea Gas Analyzers'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-3040843011282896018</id><published>2009-01-13T15:48:00.002-08:00</published><updated>2009-01-13T15:49:09.367-08:00</updated><title type='text'>Singlet-Oxygen Analyzer</title><content type='html'>* High absolute accuracy&lt;br /&gt;    * Unsurpassed sensitivity&lt;br /&gt;    * Easy to use&lt;br /&gt;&lt;br /&gt;The Quantitative Singlet-Oxygen Analyzer is designed to be readily interfaced into a variety of singlet-oxygen applications including optimization of singlet-oxygen generators, chemical oxygen-iodine laser studies, fundamental physical sciences, and plasma decontamination. Because the Analyzer is not affected by most common background gases, it provides a direct measure of singlet-oxygen density, [O2(a1∆g)], in a wide variety of these background gases with high precision (better than 1014 molecules/cm3) and a rapid response rate (data rate up to 10 Hz).&lt;br /&gt;As described in the Theory Section (on www.LGRinc.com), the measurement strategy is based on high-resolution direct-absorption spectroscopy. As a result, the instrument is self-calibrating and provides absolute, accurate measurements of singlet-oxygen density. The instrument itself can be implemented for extractive sampling, or be customized by LGR to provide in-situ measurements of O2(a1∆g) under a variety of conditions (e.g. COIL test stands, plasma effluents).&lt;br /&gt;For more information about Custom Instruments and Contract R&amp;D and for papers about Singlet-O2 Analysis, go to www.lgrinc.com.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-3040843011282896018?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/3040843011282896018'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/3040843011282896018'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/singlet-oxygen-analyzer.html' title='Singlet-Oxygen Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-9097005813879108717</id><published>2009-01-13T15:48:00.001-08:00</published><updated>2009-01-13T15:48:27.910-08:00</updated><title type='text'>CO and N2O Analyzers</title><content type='html'>* Fast measurement rate (up to 20 Hz)&lt;br /&gt;    * Unsurpassed accuracy and precision&lt;br /&gt;    * Reliable (tested on-board several NASA aircraft)&lt;br /&gt;    * Measurements of N2O and CO in single instrument possible&lt;br /&gt;&lt;br /&gt;Designed for many demanding applications including eddy-correlation flux measurements, chamber flux measurements, combustion diagnostics, and trace-gas monitoring, these Analyzers have been applied successfully on-board NASA DC-8 aircraft for trace-gas measurements in the upper troposphere / lower stratosphere. In fact, the High-Sensitivity CO Analyzer and the High-Sensitivity N2O Analyzer are ideal for measuring carbon monoxide and nitrous oxide, respectively, in ambient air with data rates of up to 10 Hz, less than 1% uncertainty (without calibration; much higher accuracy may be obtained with calibration), and better than 0.1% repeatability. Neither analyzer is affected by other atmospheric gases or changes in ambient atmospheric pressure.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-9097005813879108717?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/9097005813879108717'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/9097005813879108717'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/co-and-n2o-analyzers.html' title='CO and N2O Analyzers'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-7168440987847192762</id><published>2009-01-13T15:47:00.001-08:00</published><updated>2009-01-13T15:47:44.931-08:00</updated><title type='text'>Liquid-Water Isotope Analyzer</title><content type='html'>* Unsurpassed Precision&lt;br /&gt;    * Fast Measurements (40-80 unknown samples per day)&lt;br /&gt;    * LIMS compatible&lt;br /&gt;    * Low Power Requirements (150 Watts)&lt;br /&gt;    * Doubly Labeled Water Studies&lt;br /&gt;    * Long-Term Unattended Operation&lt;br /&gt;    * No compressed gas required&lt;br /&gt;    * Easy to Use&lt;br /&gt;    * Over 100 instruments sold worldwide&lt;br /&gt;&lt;br /&gt;The Liquid Water Isotope Analyzer provides measurements of 18O/16O and D/H (2H/1H) in liquid-water samples with unsurpassed accuracy and precision. Due to its rugged, field portable packaging, this instrument is ideal for a wide variety of hydrological, analytical, medical and biological applications that involve measurements of fresh water, sea water and biological samples (doubly labeled water studies). The Analyzer may be operated using manual injection or with an Autoinjector (optional) for autonomous injection of multiple samples. The data from the Analyzer is LIMS compatible (no extra cost).&lt;br /&gt;&lt;br /&gt;As described in the Theory Section, the measurement strategy is based on high-resolution direct-absorption spectroscopy. The instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for applications requiring unattended long-term operation), and send real-time data to a data logger through its analog and digital (RS232) outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-7168440987847192762?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/7168440987847192762'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/7168440987847192762'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/liquid-water-isotope-analyzer.html' title='Liquid-Water Isotope Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-3083487151564678323</id><published>2009-01-13T15:46:00.002-08:00</published><updated>2009-01-13T15:47:12.440-08:00</updated><title type='text'>Water-Vapor Isotope Analyzer</title><content type='html'>* Unsurpassed accuracy and precision&lt;br /&gt;    * Low power requirement (120 watts)&lt;br /&gt;    * Extremely wide range of concentrations&lt;br /&gt;    * Fast measurement response time (2 seconds)&lt;br /&gt;&lt;br /&gt;Now you can accurately measure the 18O/16O and D/H ratios in ambient water vapor (1000 ppm–saturated) rapidly with high precision (e.g., better than 0.5‰ and 2.0‰ in a measurement time of 2 seconds, respectively – of course, longer averaging times may be used to provide better precision, if desired). Our Water-Vapor Isotope Analyzer requires only 120 watts of power and does not require any sample preparation or user intervention, which enables long-term studies of water-vapor isotopes with unprecedented performance. In addition, the WVIA provides simultaneous measurements of water vapor mixing ratio [H2O] with ppm-level precision.&lt;br /&gt;&lt;br /&gt;The rugged, field-portable packaging makes this instrument ideally suited for a myriad of hydrological, atmospheric science, and industrial monitoring applications. The instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for applications requiring unattended long-term operation) and send real-time data to a data logger through its analog and digital (RS232) outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive. The instrument also includes, as standard, an embedded keyboard, mouse and monitor, for your convenience.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-3083487151564678323?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/3083487151564678323'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/3083487151564678323'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/water-vapor-isotope-analyzer.html' title='Water-Vapor Isotope Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-1758201632614995110</id><published>2009-01-13T15:46:00.001-08:00</published><updated>2009-01-13T15:46:23.000-08:00</updated><title type='text'>CO2 Isotope Analyzer</title><content type='html'>* Measures 13C/12C in carbon dioxide&lt;br /&gt;    * Extremely wide measurement range&lt;br /&gt;    * Low power requirement (120 W with internal pump)&lt;br /&gt;    * Easy to use&lt;br /&gt;&lt;br /&gt;The CO2 Isotope Analyzer is an autonomous instrument capable of measuring the 13C/12C ratio in ambient carbon dioxide with better than 0.25‰ repeatability (for an integration time of 60 seconds) and without the need for costly consumables. This is possible because the instrument itself is built around conventional telecommunications-grade diode lasers that operate in the near-infrared spectral region. In addition, since the measurement strategy is based on high-resolution direct-absorption spectroscopy (see www.LGRinc.com, Theory Section), the instrument is not affected by other atmospheric gases or by changes in ambient atmospheric pressure. Thus the need for regular calibration with expensive reference gases is also significantly reduced compared with traditional analytical instruments.&lt;br /&gt;The instrument includes an internal computer that can store data practically indefinitely on its hard drive (for applications requiring unattended long-term standalone operation), and send real-time data to a data logger through its analog, digital (RS232), and Ethernet outputs.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-1758201632614995110?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/1758201632614995110'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/1758201632614995110'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/co2-isotope-analyzer.html' title='CO2 Isotope Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-4750062628873723427</id><published>2009-01-13T15:44:00.002-08:00</published><updated>2009-01-13T15:45:46.870-08:00</updated><title type='text'>High-Accuracy CO2 Analyzer</title><content type='html'>* Unsurpassed accuracy and precision&lt;br /&gt;    * Extremely wide measurement range&lt;br /&gt;    * Low power requirement (80 watts)&lt;br /&gt;&lt;br /&gt;Insensitive to all other atmospheric gases, the High-Accuracy CO2 Analyzer measures carbon dioxide in ambient air with unprecedented accuracy and precision (total measurement uncertainty of less than 1 part in 2000). All without the need for regular external calibration. The instrument can store data practically indefinitely on its internal hard disk drive and can send real-time data to a data logger through its analog, digital (RS232), and Ethernet outputs allowing unattended long-term standalone operation.&lt;br /&gt;Based on high-resolution direct-absorption spectroscopy (see lgrinc.com, Theory Section), the instrument offers negligible zero and span drift and a significantly reduced need for regular calibration with expensive reference gases (compared with conventional instruments). The High-Accuracy CO2 Analyzer is designed for applications that require the performance of a reference laboratory without the need for regular calibration with expensive gas standards.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-4750062628873723427?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/4750062628873723427'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/4750062628873723427'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/high-accuracy-co2-analyzer.html' title='High-Accuracy CO2 Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-4821724283558889682</id><published>2009-01-13T15:44:00.001-08:00</published><updated>2009-01-13T15:44:44.055-08:00</updated><title type='text'>Methane Isotope Analyzer</title><content type='html'>* Field deployable&lt;br /&gt;    * Easy to use&lt;br /&gt;    * Unsurpassed precision&lt;br /&gt;    * Low power&lt;br /&gt;&lt;br /&gt;Due to its rugged, field-portable packaging, the Methane Isotope Analyzer is ideally suited for studies of methanogenic bacteria, methane hydrates, hydrothermal vent effluents, and other applications involving isotropic ratios in elevated levels of methane (&gt;500 ppmv). The Analyzer provides parts per mil accuracy when measuring the carbon isotope ratio (13C/12C) of methane with precision better than 1‰ and a rapid response time (2 seconds). Because it does not require any sample preparation or user-intervention, this instrument also enables long-term methane isotope monitoring studies.&lt;br /&gt;Based on high-resolution direct absorption spectroscopy, (for Theory go to lgrinc.com), the Methane Isotope Analyzer is self-calibrating and provides an absolute, accurate measurement of 13C/12C in methane without the need for expensive reference gases.&lt;br /&gt;The instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for applications requiring unattended long-term operation) and send real-time data to a data logger through its analog and digital (RS232) outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-4821724283558889682?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/4821724283558889682'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/4821724283558889682'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/methane-isotope-analyzer.html' title='Methane Isotope Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-4268887378936067136</id><published>2009-01-13T15:43:00.001-08:00</published><updated>2009-01-13T15:43:52.511-08:00</updated><title type='text'>Methane / Carbon Dioxide Analyzer</title><content type='html'>* High accuracy&lt;br /&gt;    * Wide measurement range&lt;br /&gt;    * Low power (80 W)&lt;br /&gt;&lt;br /&gt;For your convenience, we now offer two instruments for measurements of both methane and carbon dioxide simultaneously: the Fast Greenhouse Gas Analyzer and the Methane / Carbon Dioxide Analyzer. These instruments are designed to work in ambient air and to deliver accurate results over a wide range of concentrations at rapid response rates. If you require the fastest response rate (up to 20 Hz), you will want our Fast Greenhouse Gas Analyzer (CH4, CO2, H2O). For applications that call for a less expensive analyzer or do not require sub-second response rates, our Methane/Carbon Dioxide Analyzer costs less but also measures both gases simultaneously. In general, these Analyzers are not adversely affected by other atmospheric gases (i.e. no cross interferences) or changes in atmospheric pressure (no pressure broadening effects). Due to our low-power requirements, LGR analyzers may be operated on DC battery power with an appropriate AC/DC voltage inverter.&lt;br /&gt;&lt;br /&gt;The Methane/Carbon Dioxide Analyzer is designed for many applications including ambient air monitoring, chamber flux measurements, and leak detection from natural gas pipelines. As described in the Theory Section, the measurement strategy is based on high-resolution direct-absorption spectroscopy. As a result, the instrument is effectively self-calibrating. (Under extreme conditions—such as following shipment—you may wish to recalibrate the instrument. There is a Calibration mode available for this on each instrument.) Each LGR instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for applications requiring unattended long-term operation), and send real-time data to a data logger through its analog and digital outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-4268887378936067136?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/4268887378936067136'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/4268887378936067136'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/methane-carbon-dioxide-analyzer.html' title='Methane / Carbon Dioxide Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-8227485936082505487</id><published>2009-01-13T15:41:00.000-08:00</published><updated>2009-01-13T15:43:08.960-08:00</updated><title type='text'>Fast Methane Analyzer</title><content type='html'>These instruments are designed to work in ambient air and to deliver accurate results at rapid response rates. If you require the fastest response rate possible (data rate up to 20 Hz), you will want to use our Fast Methane Analyzer. For applications requiring measurements of CH4 and CO2, both our Fast Greenhouse Gas Analyzer and our Methane/Carbon Dioxide Analyzer measure both gases simultaneously. In general, LGR Analyzers are not adversely affected by other atmospheric gases (no cross interferences) or changes in ambient atmospheric pressure (no pressure broadening effects). Due to our low-power requirements, LGR analyzers may be operated on DC battery power, with an appropriate voltage inverter, and still maintain their inherent accuracy.&lt;br /&gt;&lt;br /&gt;The Fast Methane Analyzer is designed to suit many applications including eddy correlation flux measurements using established micrometeorological techniques, chamber flux measurements, and leak detection from natural gas pipelines.&lt;br /&gt;&lt;br /&gt;As described in the Theory Section, the measurement strategy is based on high-resolution direct-absorption spectroscopy. As a result, the instrument is effectively self-calibrating. (Under extreme conditions—such as following shipment—you may wish to recalibrate the instrument. There is a Calibration mode available for this on each instrument.) Each LGR instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for applications requiring unattended operation), and send real-time data to a data logger through its analog and digital (RS232) outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-8227485936082505487?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/8227485936082505487'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/8227485936082505487'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/fast-methane-analyzer.html' title='Fast Methane Analyzer'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry><entry><id>tag:blogger.com,1999:blog-4301295346690662610.post-3057993590442349058</id><published>2009-01-13T15:40:00.000-08:00</published><updated>2009-01-13T15:41:25.872-08:00</updated><title type='text'>Fast Greenhouse Gas Analyzer (CH4, CO2, H2O)</title><content type='html'>The Fast Greenhouse Gas Analyzer (FGGA) is the only instrument capable of both high accuracy and fast measurements of methane, carbon dioxide and water vapor.&lt;br /&gt;&lt;br /&gt;The FGGA is designed to work in ambient air and to deliver accurate measurements over a wide range of concentrations at rapid response rates (sufficient for eddy correlation flux applications). In particular, the FGGA reports methane, carbon dioxide and water vapor concentrations ranging from typical ambient levels to (over) ten times ambient levels with the high accuracy and reliability that you expect from LGR instruments. Also, the FGGA is not adversely affected by other atmospheric gases (no cross interferences) or changes in ambient atmospheric pressure (no pressure broadening effects). If desired, the Analyzer may be operated on DC battery power with an appropriate AC/DC inverter.&lt;br /&gt;&lt;br /&gt;The FGGA suits many applications including eddy correlation flux measurements using established micrometeorological techniques, chamber flux measurements, landfill monitoring, and leak detection from natural gas pipelines.&lt;br /&gt;&lt;br /&gt;As described in the Theory Section, the measurement strategy is based on high-resolution direct-absorption spectroscopy. The instrument includes an internal computer that can store data practically indefinitely on its internal hard drive (for applications requiring unattended long-term operation), and send real-time data to a data logger through its analog and digital (RS232) outputs. In addition, an Ethernet connection allows remote access to data files stored on the instrument’s hard drive.&lt;div class="blogger-post-footer"&gt;&lt;img width='1' height='1' src='https://blogger.googleusercontent.com/tracker/4301295346690662610-3057993590442349058?l=ultrasensitive-analyzers.blogspot.com' alt='' /&gt;&lt;/div&gt;</content><link rel='edit' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/3057993590442349058'/><link rel='self' type='application/atom+xml' href='http://www.blogger.com/feeds/4301295346690662610/posts/default/3057993590442349058'/><link rel='alternate' type='text/html' href='http://ultrasensitive-analyzers.blogspot.com/2009/01/fast-greenhouse-gas-analyzer-ch4-co2.html' title='Fast Greenhouse Gas Analyzer (CH4, CO2, H2O)'/><author><name>hearthy</name><uri>http://www.blogger.com/profile/14144454120851824045</uri><email>noreply@blogger.com</email><gd:image rel='http://schemas.google.com/g/2005#thumbnail' width='16' height='16' src='http://img2.blogblog.com/img/b16-rounded.gif'/></author></entry></feed>
